7.8.2.2 Connection
The connection interface is shown as in Figure 7-25.
Figure 7-25
Please refer to the following sheet for detailed information.
Parameter
Function
Max connection
It is the max Web connection for the same device. The value
ranges from 1 to 20. The default setup is 10.
TCP port
The default value is 37777. You can input the actual port
number if necessary.
UDP port
The default value is 37778. You can input the actual port
number if necessary.
HTTP port
The default value is 80. You can input the actual port number if
necessary.
HTTPS port
The default value is 443. You can input the actual port number
if necessary.
RTSP port
The default value is 554.
7.8.2.3 WIFI
Please note this function is for the device of WIFI module.
The WIFI interface is shown as in Figure 7-26.