HARD DRIVEP RODUCTMANUALDiamondMax™Plus 512092048D8, 91792D7, 91536D691280D5, 91024D4, 90750D3
DIAMONDMAX PLUS 5120 – INTRODUCTION1 – 9SECTION 1IntroductionMaxtor CorporationMaxtor Corporation has been providing high-quality computer storage pro
DIAMONDMAX PLUS 5120 – INTRODUCTION1 – 10ConventionsIf there is a conflict between text and tables, the table shall be accepted as being correct.Key W
PRODUCT DESCRIPTION2 – 1SECTION 2Product DescriptionMaxtor DiamondMax™ Plus 5120 AT disk drives are 1-inch high, 3.5-inch diameter random access stora
PRODUCT DESCRIPTION2 – 2Product FeaturesFunctional / InterfaceMaxtor DiamondMax™ Plus 5120 hard drives contain all necessary mechanical and electronic
PRODUCT DESCRIPTION2 – 3Logical Block AddressingThe Logical Block Address (LBA) mode can only be utilized in systems that support this form of transla
PRODUCT DESCRIPTION2 – 4Cache ManagementBuffer SegmentationThe data buffer is organized into two segments: the data buffer and the micro controller sc
PRODUCT DESCRIPTION2 – 5Major HDA ComponentsDrive MechanismA brush-less DC direct drive motor rotates the spindle at 7,200 RPM (±0.1%). The dynamicall
PRODUCT DESCRIPTION2 – 6NOITARUGIFNOCREPMUJ05J84J64J44J24JevalS/retsaM*metsysevirdelgnisnievirdylnO*metsysevirdlaudnievirdretsaMmetsysevirdlaudnievird
PRODUCT SPECIFICATIONS3 – 1SECTION 3Product SpecificationsModels and CapacitiesPerformance SpecificationsLEDOM8D840297D297196D635195D082194D420193D057
PRODUCT SPECIFICATIONS3 – 2Physical Dimensions1.028 max[25.9 mm].25 ± .011.122 ± .02[28.4 mm]1.638 ± .005[41.61 mm]1.625 ± .024.000 ± .01[101.6 mm]1.7
DiamondMax™ Plus 512092048D8, 91792D7, 91536D6, 91280D5,91024D4 and 90750D3All material contained herein Copyright © 1999 Maxtor Corporation.DiamondMa
PRODUCT SPECIFICATIONS3 – 3Power RequirementsPower Mode DefinitionsSpin-upThe drive is spinning up following initial application of power and has not
PRODUCT SPECIFICATIONS3 – 4Reliability SpecificationsAnnual Return Rate< 1.5% Annual Return Rate (ARR) indicates the average against productsshippe
PRODUCT SPECIFICATIONS3 – 5EMC/EMIRadiated Electromagnetic Field Emissions - EMC ComplianceThe hard disk drive mechanism is designed as a subassembly
INSTALLATION4 – 12SECTION 4Handling and InstallationPre-formatted DriveThis Maxtor hard drive has been formatted at the factory. Do not use a low-leve
INSTALLATION4 – 13Unpacking and InspectionRetain any packing material for reuse. Inspect the shipping container for evidence of damage in transit. Not
INSTALLATION4 – 14Figure 4 - 2Single Pack Shipping Container (Option A)Figure 4 - 3Single Pack Shipping Container (Option B)RepackingIf a Maxtor drive
INSTALLATION4 – 151Before You BeginIMPORTANT – PLEASE READ!Please read this Installation Sheet completely before installing the Maxtor hard drive. It
INSTALLATION4 – 163Hard Drive IdentificationIDE stands for Integrated Drive Electronics and EIDE is Enhanced IDE. The IDE or EIDE interface is designe
INSTALLATION4 – 174Mounting Drive in SystemTurn the computer OFF, disconnect the power cord and remove the cover. Refer to the computer user’s manual
INSTALLATION4 – 185Attaching Interfaceand Power CablesIn order for the computer to recognize that the Maxtor hard drive is in the system, the power ca
Revisions Manual No. 1410VER.ONCENOITCESNOITPIRCSED ETADAC75397llA.esaelerlaitinI 99/02/30
INSTALLATION4 – 197System SetupThe following procedures are designed for systems using the DOS 5.0 (or higher), Windows 95 and Windows 98 operating sy
INSTALLATION4 – 20Set the Cylinder, Head and Sector values with the values listed on the drive label. The drive label is located on the top cover of t
INSTALLATION4 – 213 If the BIOS was set to AUTO DETECT, follow the instructions in Section 7 to prepare the hard drive using the MaxBlast installation
AT INTERFACE DESCRIPTION5 – 22SECTION 5AT Interface DescriptionInterface ConnectorAll DiamondMax™ Plus 5120 AT drives have a 40-pin ATA interface conn
AT INTERFACE DESCRIPTION5 – 23Pin Description TablePIN NAME PIN I/O SIGNAL NAME SIGNAL DESCRIPTIONRESET - 01 I Host Reset Reset signal from the host s
AT INTERFACE DESCRIPTION5 – 24TIMING PARAMETERS MODE 0 MODE 1 MODE 2 MODE 3 MODE 4t0 Cycle Time (min) 600 ns 383 ns 240 ns 180 ns 120 nst1 Address val
AT INTERFACE DESCRIPTION5 – 25DMA TimingTIMING PARAMETERS MODE 0 MODE 1 MODE 2t0 Cycle Time (min) 480 ns 150 ns 120 nstC DMACK to DMARQ delaytD DIOR-/
AT INTERFACE DESCRIPTION5 – 26Ultra DMA TimingTIMING PARAMETERS (all times in nanoseconds)MODE 0 MODE 1 MODE 2MIN MAX MIN MAX MIN MAXtCYCCycle Time (f
AT INTERFACE DESCRIPTION5 – 27Figure 5 - 5Sustained Ultra DMA Data In BursttDVHDSTROBEat deviceDD(15:0)at deviceDSTROBEat hostDD(15:0)at hosttDVHtCYCt
AT INTERFACE DESCRIPTION5 – 28tAZtIORDYZCRCDMARQ(device)DMACK-(host)STOP(host)HDMARDY-(host)DSTROBE(device)DD(15:0)DA0, DA1, DA2,CS0-, CS1-tACKtLItMLI
Before You BeginThank you for your interest in the Maxtor DiamondMax™ Plus 5120 AT hard disk drives. This manual providestechnical information for OE
AT INTERFACE DESCRIPTION5 – 29tDHtDStDVHHSTROBEat hostDD(15:0)at hostHSTROBEat deviceDD(15:0)at devicetDVHtCYCtCYCtDVStDVStDStDHt2CYCtDHtDVHt2CYCDMARQ
AT INTERFACE DESCRIPTION5 – 30DMARQ(device)DMACK-(host)STOP(host)DDMARDY-(device)HSTROBE(host)DD(15:0)(host)tSRtRFStRPFigure 5 - 11Device Pausing an U
AT INTERFACE DESCRIPTION5 – 31DMARQ(device)DMACK-(host)STOP(host)DDMARDY-(device)HSTROBE(host)DD(15:0)(host)DA0, DA1, DA2,CS0-, CS1-tACKtMLItDVStLItLI
HOST SOFTWARE INTERFACE6 – 1SECTION 6Host Software InterfaceThe host communicates with the drive through a set of controller registers accessed via th
HOST SOFTWARE INTERFACE6 – 2Sector Count RegisterHolds the number of sectors to be sent during a Read or Write command, and the number of sectors pert
HOST SOFTWARE INTERFACE6 – 3Command RegisterContains code for the command to be performed. Additional command information should be written to thetask
HOST SOFTWARE INTERFACE6 – 4COMMAND NAME COMMAND CODE PARAMETERS USEDb7 b6 b5 b4 b3 b2 b1
HOST SOFTWARE INTERFACE6 – 5Control Diagnostic RegistersThese I/O port addresses reference three Control/Diagnostic registers:I/O PORT READ WRITE3F6h
HOST SOFTWARE INTERFACE6 – 6Reset and Interrupt HandlingReset HandlingOne of three different conditions may cause a reset: power on, hardware reset or
INTERFACE COMMANDS7 – 1SECTION 7Interface CommandsThe following section describes the commands (and any parameters necessary to execute them),as well
DIAMONDMAX PLUS 5120 PRODUCT MANUALiContentsSection 1 — IntroductionMaxtor Corporation 1 - 1Products 1 - 1Support 1 - 1Manual Organization 1 - 1Abbrev
INTERFACE COMMANDS7 – 2Read CommandsRead Sector(s)Reads from 1 to 256 sectors, as specified in the Command Block, beginning at the specified sector. (
INTERFACE COMMANDS7 – 3Read DMAMulti-word DMAIdentical to the Read Sector(s) command, except that1. The host initializes a slave-DMA channel prior to
INTERFACE COMMANDS7 – 4Set Multiple ModeEnables the controller to perform Read and Write Multiple operations, and establishes the block count forthese
INTERFACE COMMANDS7 – 5Write MultiplePerforms similarly to the Write Sector(s) command, except that:1. The controller sets BSY immediately upon receip
INTERFACE COMMANDS7 – 6Set Feature CommandsSet Features ModeEnables or disables features supported by the drive. When the drive receives this command
INTERFACE COMMANDS7 – 7Power Mode CommandsStandby Immediate – 94h/E0hSpin down and do not change time out value. This command will spin the drive down
INTERFACE COMMANDS7 – 8When enabling the Automatic Power Down sequence, the value placed in the Sector Count register ismultiplied by five seconds to
INTERFACE COMMANDS7 – 9Initialization CommandsIdentify DriveAllows the host to receive parameter information from the drive.When the command is receiv
INTERFACE COMMANDS7 – 10WORD CONTENT DESCRIPTION50 Reserved51 15-8 = PIO data transfer mode7-0 = not used52 15-8 = DMA data transfer mode7-0 = not use
INTERFACE COMMANDS7 – 11WORD CONTENT DESCRIPTION83 Command sets supported. If words 82, 83 and 84 = 0000h or FFFFh command set notification notsupport
DIAMONDMAX PLUS 5120 PRODUCT MANUALiiSection 3 — Product SpecificationsModels and Capacities 3 - 1Drive Configuration 3 - 1Performance Specifications
INTERFACE COMMANDS7 – 12Initialize Drive ParametersEnables the drive to operate as any logical drive type. The drive will always be in the translate m
INTERFACE COMMANDS7 – 13Seek, Format and Diagnostic CommandsSeekInitiates a seek to the track, and selects the head specified in the Command block.1.
INTERFACE COMMANDS7 – 14S.M.A.R.T. Command SetExecute S.M.A.R.T.The Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T.) command has been im
SERVICE AND SUPPORT8 – 1SECTION 8Service and SupportService PolicyRepairs to any DiamondMax™ Plus 5120 drive should be made only at an authorized Maxt
SERVICE AND SUPPORT8 – 2MaxFax™ ServiceUse a touch-tone phone to order Technical Reference Sheets, Drive Specifications, Installation Sheets andother
GLOSSARYGL – 1GLOSSARYGlossaryAACCESSTo obtain data from, or place data into, RAM, a register, or data storage device.ACCESS TIMEThe interval between
GLOSSARYGL – 2CYLINDEROn several disk surfaces sharing a common rotational axis, the aggregate of tracks at agiven radial position. A set of disk trac
GLOSSARYGL – 3FILE ALLOCATION TABLE (FAT)Allocates space on the disk for files, one cluster at a time; locks out unusable clusters;identifies unused (
GLOSSARYGL – 4LOGICAL ADDRESSA storage location address that may not relate directly to a physical location. Usuallyused to request information from a
GLOSSARYGL – 5RRANDOM ACCESS MEMORY (RAM)Memory designed so that any storage location can be accessed randomly, directly andindividually. This is cont
DIAMONDMAX PLUS 5120 PRODUCT MANUALiiiUltra Direct Memory Access (UDMA) 4 - 5OS Requirements for Large Capacity Hard Drives 4 - 5Hard Drive Identifica
GLOSSARYGL – 6TTHIN-FILM HEADA magnetic transducer manufactured by deposition of magnetic and electrical materialson a base material contrasted with p
M AXTOR C ORPORATION 510 COTTONWOOD D RIVE MILPITAS,CALIFORNIA 95035
DIAMONDMAX PLUS 5120 PRODUCT MANUALivDevice Control Register 6 - 5Digital Input Register 6 - 5Reset and Interrupt Handling 6 - 6Section 7 — Interface
DIAMONDMAX PLUS 5120 PRODUCT MANUALvFiguresFigure Title Page2 - 1 PCBA Jumper Location and Configuration 2 - 63 - 1 Outline and Mounting Dimensions